Products
Sephadex LH-20

Storage:RT,1 year

Sephadex LH-20
Cat.No:
S8111
Brand:
Solarbio
SKU Tongzhou Beijing Haidian Beijing Wuhan Guangzhou
S8111-25g Inquiry Inquiry Inquiry Inquiry
S8111-500g Inquiry Inquiry Inquiry Inquiry
S8111-100g Inquiry Inquiry Inquiry Inquiry
Qty:
-
+
Order now

Sephadex G-type glucan gel is only suitable for use in the aqueous phase, and the hydroxylated Sephadex LH-20 is suitable for separation of lipophilic molecules in organic solvents and purification of natural products in organic solvents.

The separation of LH-20 from glucan gel is mainly by gel filtration and has the function of reverse phase distribution.

Under the action of gel filtration, the retention of macromolecular compounds is weak, and they are eluted first, and the smallest molecules exit the column last. In the reverse-phase eluting solvent, the reverse-phase distribution effect is played. The more polar substances are eluted first, and the less polar compounds are eluted later.

Application:

The use of molecular sieve is suitable for the separation of lipophilic molecules with organic solvents, and various natural products can be prepared economically on a large scale. Such as: steroids, terpenes, lipids and small molecule polypeptides

Product parameters

Properties: porous, white microspheres

Matrix: crosslinked dextran

Size: 100-200 mesh

Working Ph:2-11

Operating temperature :4-40 degrees

Globulin separation range: 100-4000

Exclusion limit: 4-5kd(depending on the solvent used)

Storage condition: 4-25 degrees

Instructions for Use

1. Preparation of gel suspension

Soak the dry powder in 60-70% ethanol, stir well overnight, wash away any residue that may be present, and balance at least two column volumes according to your own eluent until the baseline is stable.

2. Eluting solvent

If the polarity of the sample is large, use reverse-phase solvent elution (methanol-water), dissolve the sample with the least volume of methanol-water, and filter the upper column; If the sample polarity is low, use chloroform-methanol positive phase elution.

3. Sample handling

Dissolve the sample with as little eluting reagent as possible and filter under atmospheric pressure.

4. Wet loading

Step 5 Elution

Control the flow rate, generally less than 1drop/s.

6. Next use after regeneration

Note:Product information may be optimized and upgraded. Please refer to the actual label information for accuracy.

Remark:
These protocols are for reference only. Solarbio does not independently validate these methods.

Note:
1. The products are all for scientific research use only. Do not use it for medical, clinical diagnosis or treatment, food and cosmetics, etc. Do not store them in ordinary residential areas.
2. For your safety and health, please wear laboratory clothes, disposable gloves and masks.
3. The experimental results may be affected by many factors, after-sale service is limited to the product itself and does not involve other compensation.
SERVICE FOR SCIENTIFIC RESEARCH,RESPONSIBLE FOR LIFE
Contact Us
Address: No 85, Liandong U Valley, Middle Zone, 101102, Tongzhou Dist, Beijing, China
Tel: +86 010 50973105
Technical Support Email: service@solarbio.com
Purchaser Email: purchase@solarbio.com
Sales Email: sales@solarbio.com
Copyright © 2005-2021 Solarbio all rights reserved.
 ICP Filing Certificate京ICP备12051307号-7